Wires have a non-asbestos, flexible insulation system composed of an inorganic dielectric and fused PTFE (Polytetrafluoroethylene) tape with a jacket of braided PTFE-coated glass with PTFE saturant. This construction is designed to withstand mechanical abuse plus moisture and fluid exposure as well as extreme high temperatures.
| Field | Value |
|---|---|
| Conductor Diameter | 0.056 in |
| Insulation | Outer: fused PTFE tape; Inner: inorganic dielectric |
| Jacket | Braided PTFE-coated glass with PTFE saturant |
| Weight | 14.5 lb/1000 ft. |
| 21.6 kg/1000 m. | |
| Insulation Diameter | 0.110 in |
| 2.79 mm | |
| Voltage Rating | 600 V |
| Conductor | 27 % nickel coated OFHC copper |
| Stranding | 19/29 |
| Temperature Rating | 399 ºC |
| 750 ºF | |
| Colors | Black |
| Blue | |
| Brown | |
| Green | |
| Grey | |
| Orange | |
| Red | |
| Violet | |
| White | |
| Yellow | |
| AWG Size | 16 |
| Max. Resistance @ 20ºC | 6.54 ohms/1000 ft. |
| 21.5 ohms/km. |